Fad(mm) | 551±1 |
Leithead(mm) | 110±1 |
Airde(mm) | 288±1 |
Airde Iomlán(mm) | 288±1 |
Meáchan(kg) | 44.0±3% |
Voltas Ainmniúil | 12V(6 chealla in aghaidh an aonaid) | |||
Dearadh Saol Snámh @ 25 ℃ | 10 mBliana | |||
Nominal Capacity @25℃(10 hour rate@15.0A,10.8V) | 150Ah | |||
Cumas @ 25 ℃ | Ráta 20 uair (7.95A,10.8V) ráta 5 uair (26.4A,10.5V) ráta 1 uair (95.7A,9.6V) | 159Ah132Ah 95.7Ach | ||
Friotaíocht Inmheánach | Ceallraí Luchtaithe Iomlán @ 25 ℃ | ≤3.8mΩ | ||
Teocht chomhthimpeallach | Stóráil Muirear Urscaoilte | -15 ℃ ~ 45 ℃ -15 ℃ ~ 45 ℃ -15 ℃ ~ 45 ℃ | ||
Max.Discharge Reatha@25 ℃ | 900A(5s) | |||
Acmhainn tionchar ag Teocht(10 uair) | 40 ℃ 25 ℃ 0 ℃ -15 ℃ | 105% 100% 85% 65% | ||
Féin-Urscaoileadh @ 25 ℃ in aghaidh na Míosa | 3% | |||
Muirear (Voltas Seasmhach) @ 25 ℃ | Úsáid Fuireachas | Muirearú Tosaigh Reatha Níos lú ná 37.5A Voltas 13.6-13.8V | ||
Úsáid Rothaíochta | Muirearú Tosaigh Reatha Níos lú ná 37.5AVoltage 14.4-14.9V |
Doirt Sruth Tairiseach in aghaidh na Cille (Aimpéar ag 25°C)
FV/Am | 10 nóiméad | 15 nóiméad | 30 nóiméad | 45 nóim | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
1.60V | 348.8 | 270.8 | 162.5 | 120.8 | 95.7 | 56.3 | 41.4 | 27.9 | 19.1 | 15.8 | 8.33 |
1.65V | 322.7 | 255.8 | 157.1 | 116.1 | 92.9 | 54.5 | 40.1 | 27.5 | 18.9 | 15.5 | 8.25 |
1.70V | 299.3 | 240.2 | 152.7 | 111.9 | 89.3 | 53.0 | 39.0 | 26.9 | 18.6 | 15.3 | 8.16 |
1.75V | 279.5 | 225.0 | 144.8 | 107.0 | 85.7 | 51.6 | 38.1 | 26.4 | 18.3 | 15.2 | 8.09 |
1.80V | 251.4 | 211.1 | 139.7 | 103.1 | 82.7 | 49.7 | 36.9 | 25.8 | 18.0 | 15.0 | 7.95 |
Doirt Cumhacht Tairiseach in aghaidh na Cille (Watanna ag 25°C)
FV/Am | 10 nóiméad | 15 nóiméad | 30 nóiméad | 45 nóim | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
1.60V | 627.3 | 517.7 | 316.7 | 229.4 | 183.6 | 106.7 | 79.1 | 53.9 | 37.2 | 30.8 | 16.1 |
1.65V | 587.1 | 495.3 | 302.9 | 221.6 | 178.7 | 103.8 | 77.0 | 53.0 | 36.9 | 30.5 | 15.9 |
1.70V | 549.8 | 461.6 | 290.4 | 214.5 | 172.5 | 101.4 | 75.2 | 52.2 | 36.5 | 30.2 | 15.8 |
1.75V | 517.4 | 433.1 | 276.5 | 206.0 | 166.2 | 99.0 | 73.7 | 51.5 | 36.0 | 29.9 | 15.6 |
1.80V | 468.3 | 406.5 | 265.2 | 199.1 | 160.8 | 95.7 | 71.6 | 50.4 | 35.6 | 29.7 | 15.5 |
Nóta: Is meánluachanna iad na sonraí thuas, agus is féidir iad a fháil laistigh de 3 thimthriall luchtaithe/scaoilte.Ní íosluachanna iad seo.Tá dearaí/sonraíochtaí cille agus ceallraí faoi réir modhnú gan fógra.Déan teagmháil le CSBBattery chun an fhaisnéis is déanaí a fháil.
Comhpháirt | Pláta dearfach | Pláta diúltach | Coimeádán & Clúdach | Comhla sábháilteachta | Teirminéal | Deighilteoir | Leictrilít | Muir cholún |
Gnéithe | Greille tiubh ard Sn íseal Ca le greamaigh speisialta | Greille cothromaithe Pb-Ca le haghaidh éifeachtúlachta feabhsaithe | Frithsheasmhacht dóiteáin ABS (UL94-V0 roghnach) | Flame Si-Rubber agus friotaíocht ag dul in aois | Copar Mná Ionsáigh M6(torc :3~4N.m | Ardchruinniú Cinn Bhliana deighilteoir le haghaidh dearadh cille ardbhrú | Caolaigh aigéad sulfarach ardíonachta | Séala roisín eapocsa dhá shraith |